Topaloglu, S.Sagbas, M.Anday, F.2024-07-122024-07-1220121434-841110.1016/j.aeue.2011.12.0092-s2.0-84861578686https://dx.doi.org/10.1016/j.aeue.2011.12.009https://hdl.handle.net/20.500.12415/7726In this study, a novel second order universal filter using current-feedback amplifier, commercially available active component, is presented. The signal-flow graph method is used to synthesize the filter. The proposed filter has three high impedance input and one output, (multiple input single output (MISO) configuration). It can generate all biquadratic filtering functions namely: low-pass (LP), band-pass (BP), high-pass (HP), band-reject (BR) and all-pass (AP) at the output terminal by selecting different input signal combinations. The validity of the proposed circuits is demonstrated by simulations. (C) 2011 Elsevier GmbH. All rights reserved.eninfo:eu-repo/semantics/closedAccessCurrent feedback operational amplifiersSignal-flow graphVoltage transfer function circuitsActive filtersUniversal biquadsThree-input single-output second-order filters using current-feedback amplifiersArticle6868Q268366WOS:000305815300015Q3