dc.description.abstractBackground Potential interference between implanted cardiac devices and other medical instruments is an important concern. Therefore, we aimed to investigate the possible device interaction between implantable cardioverter defibrillators (ICDs) and external enhanced counterpulsation (EECP) treatment. Methods Twenty-one patients with an implanted ICD or cardiac resynchronization therapy with defibrillator (CRT-D) were enrolled into the study. EECP had applied as two sessions of 5 minutes. Data from device interrogations before and after the first EECP session and during second EECP session were recorded and analyzed for signs of possible device interaction. Results There was no sign of inappropriate sensing or noise during EECP session. There was no difference regarding electrode impedance, pacing, and sensing values before and after EECP. There was a statistically significant difference regarding heart rates during EECP therapy between rate response off and on modes (68.69 +/- 5.92 beats/min and 90.32 +/- 11.05 beats/min, respectively P = 0,001). In four patients with CRT-D and unipolar left ventricular pacing, counterpulsation could not be done because of QRS sensing problems. Conclusions EECP seems to be a safe treatment modality in patients with implanted ICD and CRT-D devices. It should be kept in mind that in those patients with CRT-D, rate responsive mode is on; inappropriate sinus tachycardia can be seen during EECP therapy. Also in patients with CRT-D using a unipolar sensing mode, problems of QRS complex sensing by the EECP may occur and, therefore, this effects synchronization and success of EECP therapy.en_US
dc.language.isoengen_US
dc.publisherWILEY-BLACKWELLen_US
dc.relation.isversionof10.1111/pace.12178en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectimplantable cardioverter defibrillatoren_US
dc.subjectenhanced external counterpulsationen_US
dc.subjectheart failureen_US
dc.subjectEECPen_US
dc.titleInteraction between Cardioverter Defibrillator and Enhanced External Counterpulsation Deviceen_US
dc.typearticleen_US
dc.relation.journalPACE-PACING AND CLINICAL ELECTROPHYSIOLOGYen_US
dc.contributor.departmentMaltepe Üniversitesien_US
dc.identifier.volume36en_US
dc.identifier.issue9en_US
dc.identifier.startpage1104en_US
dc.identifier.endpage1106en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record