Yazar "Karaman, O." seçeneğine göre listele
Listeleniyor 1 - 2 / 2
Sayfa Başına Sonuç
Sıralama seçenekleri
Yayın A comparison of full arthroscopic and arthroscopic-assisted mini-open repair methods in rotator cuff tears 1-3 cm in size(ELSEVIER SCIENCE BV, 2018) Karaman, O.; Karakus, O.; Saygi, B.Introduction: Retrospective evaluation of rotator cuff repair with arthroscopic or arthroscopic-assisted mini-open methods for a diagnosis of non-retracted rotator cuff tear. Materials and methods: A total of 45 patients underwent rotator cuff repair; Group 1 (n=24) with arthroscopic-assisted mini-open method and Group 2 (n=21) with full arthroscopic method. Results: Within both Group 1 and Group 2, a statistically significant results is p=0.001. The patients of Group 2 were seen to return to daily life earlier than those of Group 1 (p=0.001). Conclusions: Patients where full arthroscopic repair was applied, there was evidence of an earlier return to daily life. Level of evidence: IV, retrospective comparative study.Yayın Effects of reinforcing materials on durability of bone cement: in vitro experimental study(BMC, 2018) Karakus, O.; Karaman, O.; Gurer, B.; Saygi, B.Background: Bone cement is one of the most commonly used products in orthopedic surgery. Among common indications for its use are total joint replacement, bone and joint reconstructions, fracture fixation, treatment of bone infections, and treatment of osteoporotic vertebral fractures. Endurance is still questionable. The aim of our study is to find out the effect of structure strengtheners on compression pressure measurements of bone cement. Methods: There were four groups in this study: group 1, 40 cm(3) pure bone cement (PMMA); group 2, 40 cm3 bone cement with %25 titanium dust; group 3, 40 cm(3) bone cement with %25 steel dust; and group 4, 40 cm(3) bone cement with %25 silica fume mixtures were prepared. These mixtures were frozen in 6-mm-width, 12-mm-height molds in cylindrical shape. Axial compression was made to these molds. Results: Compression pressure measurements of the pure cement group ranged between 79.2 and 81.1 MPa; average was 80.25 +/- 0.42 MPa. Measurements of titanium-added group ranged from 79.5 to 81.2 MPa; average was 80.46 +/- 0.68 MPa. Steel-added group ranged from 79 to 82.2 MPa; average was 80.73 +/- 0.57 MPa. For silica fume, measurements ranged from 89.1 to 91.4 MPa and average was 90.41 +/- 0.57 MPa. The highest compression pressure values were gathered from the silica fume (p = 0.001). Conclusion: The construction reinforcer silica fume could be mixed with PMMA homogeneously and was superior to the other biocompatible materials that we had used in compression pressure tests. Beyond dispute, silica fume is a reinforcer which also increases the strength of the bone cement.