Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Araştırmacılar
  • Projeler
  • Birimler
  • Analiz
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Kaya Ö." seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Küçük Resim Yok
    Yayın
    Real-time three-dimensional left ventricular contraction in patients with diastolic dysfunction
    (Springer Tokyo, 2016) Hatipoğlu S.; Babur Güler G.; Kaya Ö.; Kahveci G.; Güler E.; Eroğlu E.; Özdemir N.
    Purpose: Systolic alterations in left ventricular (LV) myocardial function have been reported previously in patients with diastolic dysfunction (DD). Recent advances in real-time three-dimensional echocardiography (3DE) enable the measurement of a set of parameters previously difficult to obtain with standard two-dimensional echocardiography (2DE). The aim of this study was to evaluate global 3DE LV contraction in patients with and without DD who had normal ejection fraction (EF). Methods: Sixty-five patients (average age 56 ± 6 years; 31 females and 34 males) with normal EF (>50 %) referred to echocardiographic examination for the evaluation of DD were included. In addition to measuring conventional echocardiographic parameters, they were also evaluated with 3DE. End diastolic volume, end systolic volume, EF, corrected standard deviation (SD) of time to minimal systolic volume for 16 segments its dispersion, average excursion of the segments and the SD of segmental motion (excursion-SD) were recorded. Results: When we tested the differences among three groups of diastolic function (normal, Grade 1, and Grade 2), the results showed that coronary artery disease, left atrial volume, septum, posterior wall, E, A, E/A, deceleration time, E' septum, E' lateral, and excursion-SD were significantly different. An ordered logistic regression analysis revealed that excursion-SD (p < 0.001) and septum (p < 0.001) measurements were statistically significant for predicting DD grade. Conclusion: In our patient population, a decline in excursion-SD values was observed with increasing DD grade. In other words, the amount of segmental difference in terms of excursion was reduced. © 2016, The Japan Society of Ultrasonics in Medicine.

| Maltepe Üniversitesi | Kütüphane | Açık Bilim Politikası | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Maltepe Üniversitesi Kütüphane ve Dokümantasyon Daire Başkanlığı, İstanbul, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim