Sağ kalp basınç ve volüm yükü durumunda trikuspit kapak anulus doku doppler parametrelerinin karşılaştırılması

dc.authorid0000-0002-2858-4023en_US
dc.authorid0000-0003-4642-8590en_US
dc.authorid0000-0003-1407-5313en_US
dc.authorid0000-0002-5634-1280en_US
dc.contributor.authorÖzmen, Namık
dc.contributor.authorYiğiner, Ömer
dc.contributor.authorKunter, Erdoğan
dc.contributor.authorKardeşoğlu, Ejder
dc.contributor.authorÜnver, Suat
dc.contributor.authorAparcı, Mustafa
dc.contributor.authorDinçtürk, Mehmet
dc.date.accessioned2024-07-12T21:10:09Z
dc.date.available2024-07-12T21:10:09Z
dc.date.issued2006en_US
dc.departmentFakülteler, Tıp Fakültesien_US
dc.description.abstractAmaç: Sağ kalp fonksiyonlarını standart ekokardiografi ile değerlendirmek zordur. Ancak doku Doppler (DD) bu amaç­la kullanılabilir. Çalışmamızda sağ kalp basınç ve volüm yüklenmesi durumunda trikuspit anulus DD pa­ra­met­re­lerini karşılaştırdık. Gereç ve Yöntem: Çalışmaya volum yükü olarak 35 kronik hemodiyaliz hastası ile basınç yükü olarak yeterli te­da­vi almayan 35 semptomatik (dekompanze) KOAH hastası ve benzer yaş grubunda 35 sağlıklı birey kontrol grubu ola­rak alındı. Her üç grubun trikuspit medial ve lateral anulus DD; sistolik S, erken diastolik E’ ve geç diastolik A’ dal­ga zirve hızları, pulmoner arter sistolik sistolik basıncı (PASB) ve sağ atrium çapı (SAÇ) ölçüldü. Dekompanze KOAH ve diyaliz öncesi bulgular kontrol grubu ile, tedavi öncesi-sonrası KOAH hastaları kendi bulgularıyla ve di­ya­liz öncesi-sonrası diyaliz hastalarının kendi bulguları student-t testi ile karşılaştırıldı, p<0.05 ise istatistisel olarak an­lamlı kabul edildi Bulgular: Kontrol grubuyla karşılaştırıldığında; dekompanze KOAH hastalarında hem medial hem de lateral tri­kus­pit anulus zirve hızları yüksek iken, hemodiyaliz öncesi sadece trikuspit lateral anulus zirve hızları daha yük­sek­ti. Optimal tedavi sonrası KOAH hastalarında PASB azalırken, DD zirve hızlarında ve SAÇ’ında anlamlı azalma ol­ma­dı. Hemodiyaliz sonrası ise diyaliz hastalarının, PASB, SAÇ ve trikuspit lateral anulus zirve hızlarında anlamlı azal­ma gözlendi Sonuç: Trikuspit kapak anulus DD çalışması sağ kalp fonksiyonklarını değerlendirmede, basınç ve volum yük­len­me­sinin ayırt edilmesinde kullanılabiliren_US
dc.description.abstractAim: Assessment of right ventricular functions by using standard echocardiography is a common difficulty. And tissue Doppler (TD) is a method that can be used for this purpose. So we compared tissue Doppler parameters of tricuspid annulus obtained in the condition of right ventricular pressure and volume overload in our study. Material and Methods: Thirty five chronic hemodialysis patients with volume overload and 35 symptomatic patients with chronic obstructive pulmonary disease ineffectively treated as pressure overload and also age and sex matched 35 healthy individuals as control group were enrolled to the study. Tissue Doppler parameters derived medial and lateral annulus of tricuspid valve; e.g. peak velocities of systolic S wave, early diastolic E' wave, late diastolic A' wave; pulmonary artery systolic pressure (PASP) and right atrial diameter (RAD) were obtained from each groups. Results of groups with exaggerated COPD and pre-dialysis were compared with the findings of control group. Also results of patients with COPD derived before and after the treatment and results of chronic hemodialysis patients derived before and after dialysis were compared each other within each group by using student-t test. P values less than 0.05 were accepted significant. Results: Whereas peak velocities of both medial and lateral tricuspid annulus derived from the patients with COPD exaggeration were higher in comparison to the control group, only peak velocities of lateral tricuspid annulus were found to be higher in pre-dialysis patients. While PASP was decreasing with the optimal therapy in the patients of COPD, peak velocities in TD and RAD did not decrease significantly. PASP, RAD and peak velocities of tricuspid lateral annulus were found to be decreased after hemodialysis. Conclusion: TD of tricuspid valve annulus may be useful in the assessment of right ventricular functions and also in the discrimination of volume or pressure overload.en_US
dc.identifier.citationÖzmen, N., Yiğiner, Ö., Kunter, E., Kardeşoğlu, E., Ünver, S., Aparcı, M, Cingözbay, B. Y. ve Dinçtürk, M. (2006). Sağ kalp basınç ve volüm yükü durumunda trikuspit kapak anulus doku doppler parametrelerinin karşılaştırılması / Comparison of tissue doppler parameters derived from tricuspid annulus in the condition of right ventricular pressure and volume overload. Medical Network, Medikal Yayıncılık. s. 161-166.en_US
dc.identifier.endpage166en_US
dc.identifier.issn1300-4778
dc.identifier.startpage161en_US
dc.identifier.urihttp://www.medicalnetwork.com.tr/2006/konu.asp?goster=1&Metin=303
dc.identifier.urihttps://hdl.handle.net/20.500.12415/4194
dc.institutionauthorCingözbay, Bekir Yılmaz
dc.language.isotren_US
dc.publisherMedikal Yayıncılıken_US
dc.relation.ispartofMedical Networken_US
dc.relation.publicationcategoryUlusal Hakemli Dergide Makale - Kurum Öğretim Elemanıen_US
dc.rightsCC0 1.0 Universal*
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rights.urihttp://creativecommons.org/publicdomain/zero/1.0/*
dc.snmzKY02893
dc.subjectTrikuspit kapak anulus doku Doppleren_US
dc.subjectBasınç yüküen_US
dc.subjectVolum yüküen_US
dc.subjectTricuspid valve annulus tissue Doppleren_US
dc.subjectVolume overloaden_US
dc.subjectPressure overloaden_US
dc.titleSağ kalp basınç ve volüm yükü durumunda trikuspit kapak anulus doku doppler parametrelerinin karşılaştırılmasıen_US
dc.title.alternativeComparison of tissue doppler parameters derived from tricuspid annulus in the condition of right ventricular pressure and volume overloaden_US
dc.typeArticle
dspace.entity.typePublication

Dosyalar