Novel lateral support system increases stability and reduces angular error in total hip arthroplasty: a case control study

dc.authorid0000-0001-6861-6555en_US
dc.authorid0000-0002-9445-2211en_US
dc.authorid0000-0001-7851-3920en_US
dc.authorid0000-0003-1829-5700en_US
dc.contributor.authorDağtaş, Mirza Zafer
dc.contributor.authorÜnal, Ömer Kays
dc.contributor.authorNajafov, Turan
dc.contributor.authorUgutmen, Ender
dc.date.accessioned2024-07-12T21:04:55Z
dc.date.available2024-07-12T21:04:55Z
dc.date.issued2022en_US
dc.departmentFakülteler, Tıp Fakültesien_US
dc.description.abstractBackground/Aim: Intraoperative changes in patient position or other changes that would disrupt the decisive position during preoperative preparation would directly have a negative impact on acetabular cup orientation in patients undergoing total hip arthroplasty. This study aimed to compare the standard support system and a novel lateral support system (Maltepe), which ensures stable lateral decubitus positioning during the perioperative period, in patients undergoing total hip arthroplasty with the posterolateral approach. Methods: Patients operated in our department for osteoarthritis of the hip between 2012 - 2019 were included in this case-control study retrospectively. 46 and 41 patients were prepared for surgery in lateral decubitus position using the classical (Group 1) and novel (Group 2) lateral support systems, respectively. The groups were compared in terms of demographic characteristics, duration of preparation, anteversion and inclination, and Harris Hip scores. Results: Mean patient age was 66.89 (7.53). There was no significant difference between the two groups in terms of age (P=0.546), gender (P=1.00), body mass index (P=0.302) and the operative side (P=0.724). Duration of preparation and absolute deviation values from 15 degrees and 45 degrees were significantly better in group 2 compared to group 1 (P<0.01). There was no significant difference between the Harris Hip Scores of two groups. Conclusion: We demonstrated that the novel support system we developed provided more successful outcomes than the classical system in terms of acetabular cup orientation.en_US
dc.identifier.citationDağtaş, M.Z., Ünal, Ö.K., Najafov, T., Ugutmen, E. (2022). Novel lateral support system increases stability and reduces angular error in total hip arthroplasty: A case control study. Journal of Surgery and Medicine, 6(2), p.186-190.en_US
dc.identifier.endpage190en_US
dc.identifier.issue2en_US
dc.identifier.startpage186en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12415/3852
dc.identifier.volume6en_US
dc.language.isoenen_US
dc.publisherJOSAMen_US
dc.relation.ispartofJournal of Surgery and Medicineen_US
dc.relation.isversionof10.28982/josam.1049928en_US
dc.relation.publicationcategoryUluslararası Hakemli Dergide Makale - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.snmzKY02048
dc.subjectArthroplastyen_US
dc.subjectHipen_US
dc.subjectLateral decubitusen_US
dc.subjectSurgical preparation timeen_US
dc.subjectSurgical positioningen_US
dc.titleNovel lateral support system increases stability and reduces angular error in total hip arthroplasty: a case control studyen_US
dc.typeArticle
dspace.entity.typePublication

Dosyalar