Diagnosis of the prosthetic heart valve pannus formation with real-time three-dimensional transoesophageal echocardiography

Küçük Resim Yok

Tarih

2010

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Oxford Univesity Press

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Araştırma projeleri

Organizasyon Birimleri

Dergi sayısı

Özet

Prosthetic heart valve obstruction (PHVO) caused by pannus formation is an uncommon but serious complication. Although twodimensional transesophageal echocardiography (2D-TEE) is the method of choice in the evaluation of PHVO, visualization of pannus is almost impossible with 2D-TEE. While demonstrating the precise aetiology of PHVO is essential for guiding the therapy, either thrombolysis for valve thrombosis or surgery for pannus formation, more sophisticated imaging techniques are needed in patients with suspected pannus formation. We present real-time 3D-TEE imaging in a patient with mechanical mitral PHVO, clearly demonstrating pannus overgrowth.

Açıklama

Anahtar Kelimeler

Prosthetic heart valve, Pannus formation, Three-dimensional transesophageal, Echocardiography

Kaynak