Efficacy and safety of 120w greenlight photoselective vaporisation of prostate in patients receiving anticoagulant drugs
Küçük Resim Yok
Tarih
2013
Yazarlar
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Erişim Hakkı
info:eu-repo/semantics/closedAccess
Özet
Objective: To evaluate the efficacy and safety of photoselective prostate vapourisation with 120w potassium titanyl phosphate laser in benign prostate hyperplasia patients receiving oral anti-coagulant therapy. Methods: The retrospective study was conducted at Istanbul Hisar International Hosptial and comprised 63 male patients who were on anti-coagulant therapy for comorbidities and who underwent prostate vapourisation for benign prostate hyperplasia with 120 Watts potassium titanyl phosphate from November 2007 to December 2010. International Prostate Symptoms Score, Quality of Life scores, uroflowmetry pre-operatively and 3 months postoperatively were obtained. Ultrasound examination was performed for each patient to evaluate prostate and residual urine in the bladder. Plasma haemoglobin, haematocrit and International Normalised Ratio levels were also checked for patients in the pre-and post-operative period. Results: The age range of the patients was from 65-89 years with a mean of 72.3±8 years. The mean prostate weight was 45±17ml (range: 40-120). Mean operation time was 54±16 minutes (25-90). The removal of urinary catheter took place 1-3 days post-operatively. None of the patients required transfusion. The International Prostate Symptoms Score was reduced (23±6 vs 14±3) at third month after the operation. Quality of Life scores were improved from 2.2±1.1 to 4.7±1.2, and maximal urine flow rate increased from 7.8±2.3 to 16±1 in the same period. Urinary obstruction due to clot retention was observed in 1 (1.58%) patient in post-operative 3 days. Urinary retention occurred in 5 (7.98%) patients after the removal of the urinary catheter. Permanent urinary retention, peroperative bleeding and post-operative incontinence were not observed. Conclusion: Treatment of benign prostate hyperplasia with photoselective prostate vapourisation is effective and safe in patients receiving anti-coaguant therapy. However, patients should be monitored in early post-operative period for macroscopic haematuria and transient urinary retention.
Açıklama
Anahtar Kelimeler
Anticoagulant therapy, Benign prostate hyperplasia, Photoselective prostate vaporization
Kaynak
Journal of the Pakistan Medical Association
WoS Q Değeri
Q4
Scopus Q Değeri
Q4
Cilt
63
Sayı
12