A Comparison Study Between Four Different Pachymeters to Measure Corneal Thickness

dc.contributor.authorÇağlar, Ç.
dc.date.accessioned2024-07-12T21:40:14Z
dc.date.available2024-07-12T21:40:14Z
dc.date.issued2022en_US
dc.department[Belirlenecek]en_US
dc.description.abstractTo compare the correlation and agreement between the central corneal thickness (CCT) measurements with ultrasound pachymeter and three different non-contact pachymeters and to analyze their influence on intraocular pressure (IOP) measurements. This prospective study included 102 healthy adults. Optical biometer (OB), scheimpflug corneal topographer (TOPO), ultrasound pachymeter (UP), and non-contact pachytonometer (NCP) were carried out to measure the corneal thickness. Pearson and Spearman correlation and a 95% limit of agreement were calculated. In this prospective study, the CCT of 102 right eyes of 102 healthy volunteers were analyzed. CCT measured with optic biometer, corneal topography, ultrasound pachymeter and non-contact pachytonometer were 534.7 (438-629), 544.8 (444-634), 553.1 (449-674) and 562.9 (464-665 µm), respectively. There were strong correlations between all pachymeters by Pearson correlation analysis. The correlation of Pearson between all measurement methods were over 0.9 50. When the CCT was divided into the three groups according to corneal thickness ranges, the correlation was higher than 0.7 in all groups (r=0.72-0.91 for <510 µm, r=0.85-0.95 for 510-580 µm, r=0.82-0.93 for >580 µm) by Spearman correlation analysis. A significant positive correlation was observed between the IOP values and CCT obtained by all pachymeters with a trend toward increasing the IOP with increasing corneal thickness. The correlations between the pachymeters were high in normal corneal thicknes s, whereas it was slightly lower in the thick and thin cornea. A significant positive correlation was observed between IOP and CCT in all pachymeters. © 2022, Yuzuncu Yil Universitesi Tip Fakultesi. All rights reserved.en_US
dc.identifier.doi10.5505/ejm.2022.93763
dc.identifier.endpage640en_US
dc.identifier.issn1301-0883
dc.identifier.issue4en_US
dc.identifier.scopus2-s2.0-85140043708en_US
dc.identifier.scopusqualityQ4en_US
dc.identifier.startpage634en_US
dc.identifier.trdizinid1175754en_US
dc.identifier.urihttps://doi.org/10.5505/ejm.2022.93763
dc.identifier.urihttps://search.trdizin.gov.tr/yayin/detay/1175754
dc.identifier.urihttps://hdl.handle.net/20.500.12415/7180
dc.identifier.volume27en_US
dc.indekslendigikaynakScopus
dc.indekslendigikaynakTR-Dizin
dc.language.isoenen_US
dc.publisherYuzuncu Yil Universitesi Tip Fakultesien_US
dc.relation.ispartofEastern Journal of Medicineen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.snmzKY05048
dc.subjectAl-Scan Optic Biometeren_US
dc.subjectCentral Corneal Thicknessen_US
dc.subjectSirius Corneal Topographeren_US
dc.subjectTrk-2p Non-Contact Pachytonometeren_US
dc.subjectUltrasound Pachymeteren_US
dc.titleA Comparison Study Between Four Different Pachymeters to Measure Corneal Thicknessen_US
dc.typeArticle
dspace.entity.typePublication